GDC ATM Switch Install vbs script

Here is an MS Windows .vbs script.

This Script is used to guide an user to completly erase an GDC ATM switch and send new firmware and configuration files on it.
For working, this script must found directory slot0,slot1,slot2, etc... containing requiered file

Example of file hierarchy needed for this script:
\switch1\slot0\startup_isg.tz
\switch1\slot0\config.cfg
\switch1\slot1\config.cfg
\switch1\slot1\mpro1.cod
etc..

This script will check the files and found the type of corresponding card type

Copy past the following code in a text file, an save it with the name GDC-install.vbs



' GDC ATM Switch Install
' Release 0.67

Main()

Sub Main()

    RELEASE = "GDC ATM Switch Install for dummies - release 0.67"
    TEXT = "This tools will help you to erase all memory flash on a GDC ATM Switch"
    TEXT = TEXT & " and re-injecting the new firmware and configuration files" & vbCrLf & vbCrLf
    TEXT = TEXT & "Pre-requise:" & vbCrLf
    TEXT = TEXT & "You need to put GDC ATM firmware and configuration files" & vbCrLf
    TEXT = TEXT & "These subfolders must use this convention name:" & vbCrLf
    TEXT = TEXT & "- slot0 that contain a minimum of 3 files files: startup_isg.tz, config.cfg and hosts" & vbCrLf
    TEXT = TEXT & "- slot1 that contain files corresponding to the card type insered in this slot" & vbCrLf
    TEXT = TEXT & "- slot2, the same: files corresponding to the card type" & vbCrLf
    TEXT = TEXT & "- etc..." & vbCrLf& vbCrLf
    TEXT = TEXT & "Your IP configuration of your Workstation must be correctly configured with these parameters:" & vbCrLf
    TEXT = TEXT & " - IP address: 172.16.255.2" & vbCrLf
    TEXT = TEXT & " - IP MASK: 255.255.0.0" & vbCrLf
    TEXT = TEXT & " - IP Gateway: 172.16.255.1" & vbCrLf
    TEXT = TEXT & " and your NIC must be connected on the ATM Switch MGNT port of the STANDBY ISG card! (and not the ISG card on the slot0)" & vbCrLf & vbCrLf
    TEXT = TEXT & "Warning: Make sur your laptop is connected on the power supply outlet before starting this procedure" & vbCrLf & vbCrLf
    RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
    If RESPONSE = 2 Then
        wscript.quit
    End If
   
    Check_file()

    TEXT = "Step 2: Erasing all flash memory for each controler card:" & vbCrLf & vbCrLf
    TEXT = TEXT & "1. Power off the ATM switch" & vbCrLf& vbCrLf
    TEXT = TEXT & "2. Extract all cards (with the exception of XH cards) and change their rotary switch position to F" & vbCrLf & vbCrLf
    TEXT = TEXT & "3. Re-insert all cards and Power on the ATM switch" & vbCrLf & vbCrLf
    TEXT = TEXT & "4. Wait for the leds of each card (with the exception of EC2 cards) blink very fast :this indicates that the flash have been erased (aprox 5 minutes)" & vbCrLf & vbCrLf
    TEXT = TEXT & "5. Power off the ATM switch" & vbCrLf & vbCrLf
   
    TEXT = TEXT & "6. Change the rotary switch position by extracting each card (except for XH card):" & vbCrLf
    TEXT = TEXT & "- ISG card and Standby ISG card in position 1" & vbCrLf
    TEXT = TEXT & "- All other cards in position 9" & vbCrLf & vbCrLf
    TEXT = TEXT & "7. Re-insert only the standby ISG card (the XH card are still insered)" & vbCrLf & vbCrLf
    TEXT = TEXT & "8. Power on the ATM switch" & vbCrLf & vbCrLf
    TEXT = TEXT & "9. Wait until the ATM switch is running:" & vbCrLf & vbCrLf
    TEXT = TEXT & "- LED Status for standby ISG card: FLT and RUN are alternatively blinking" & vbCrLf & vbCrLf
    TEXT = TEXT & "Click OK only when ATM switch is ready"
    RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
    If RESPONSE = 2 Then
        wscript.quit
    End If
   
    iptest=check_ip("172.16.255.2","255.255.0.0","172.16.255.1")
   
    if iptest=0 then
        TEXT = "Your IP address is not configured correctly or interface down" & vbCrLf
        RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
        If RESPONSE = 2 Then
            wscript.quit
        End If
    End If
   
    TEXT = "Now, we will check IP connectivity by pinging the standby ISG card" & vbCrLf
    TEXT = TEXT & "Click OK for send a ping to the Standby ISG card"
    RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
    If RESPONSE = 2 Then
        wscript.quit
    End If
   
    Set WshShell = WScript.CreateObject("WScript.Shell")

    RETURNCODE = WshShell.Run("ping 172.16.255.1 -n 1", 1, True)
    if RETURNCODE > 0 then
        TEXT = "ERROR for ping the Standby ISG card!" & vbCrLf
        TEXT = TEXT & "Check your workstation IP configuration and cabling!" & vbCrLf
        RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
        If RESPONSE = 2 Then
            wscript.quit
        End If
    end if
   
    TEXT = "IP Connectivty is OK" & vbCrLf & vbCrLf
    TEXT = TEXT & "Step 3: Sending firmware file into the Standby ISG card." & vbCrLf
    TEXT = TEXT & "Click OK for proceding to files transfert"
    RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
    If RESPONSE = 2 Then
        wscript.quit
    End If
   
    FTP_isg()
   
    TEXT = "File should be transferted on the Standby ISG card" & vbCrLf & vbCrLf
    TEXT = TEXT & "Step 4: Sending initial configurations and hosts file into the ISG card." & vbCrLf & vbCrLf
    TEXT = TEXT & "1. Power off the ATM switch" & vbCrLf & vbCrLf
    TEXT = TEXT & "2. Unplug your workstation Ethernet cable from the standby ISG card and plug it on the ISG card" & vbCrLf & vbCrLf
    TEXT = TEXT & "3. Extract the Standby ISG card and change the rotary switch position to 4 but do not re-insert it!: This card will be insered only at the end of this procedure" & vbCrLf & vbCrLf
    TEXT = TEXT & "4. Re-insert all other cards with the expection of the Standby ISG card" & vbCrLf & vbCrLf
    TEXT = TEXT & "5. Power on the ATM switch" & vbCrLf & vbCrLf
    TEXT = TEXT & "6. Wait until the ATM switch is running:" & vbCrLf & vbCrLf
    TEXT = TEXT & "- LED Status for ISG card: FLT and RUN are alternatively blinking" & vbCrLf & vbCrLf
    TEXT = TEXT & "Click OK only when ATM switch is ready"
    RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
    If RESPONSE = 2 Then
        wscript.quit
    End If
   
    TEXT = "Now, we will check IP connectivity by pinging ISG card" & vbCrLf
    TEXT = TEXT & "Click OK for send a ping to the ISG"
    RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
    If RESPONSE = 2 Then
        wscript.quit
    End If

    RETURNCODE = WshShell.Run("ping 172.16.255.1 -n 1", 1, True)
    if RETURNCODE > 0 then
        TEXT = "ERROR for ping the ISG card!" & vbCrLf
        TEXT = TEXT & "Check your workstation IP configuration and cabling!" & vbCrLf
        RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
        If RESPONSE = 2 Then
            wscript.quit
        End If
    end if
   
    TEXT = "IP Connectivty is OK" & vbCrLf & vbCrLf
    TEXT = TEXT & "Step 5: Sending firmware and initial configuration files into the ISG." & vbCrLf
    TEXT = TEXT & "Click OK for proceding to files transfert"
    RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
    If RESPONSE = 2 Then
        wscript.quit
    End If
   
    FTP_isg()
   
    TEXT = "Step 6: Change the rotary switch of the ISG card (slot0) to 0"  & vbCrLf  & vbCrLf
    TEXT = TEXT & "1. Extract the ISG card (slot0) and put the rotary swith in position 0"  & vbCrLf & vbCrLf
    TEXT = TEXT & "2. Re-insert the ISG card (slot0)"  & vbCrLf & vbCrLf
    TEXT = TEXT & "3. Click OK ONLY when (after about 5 minutes):"  & vbCrLf & vbCrLf
    TEXT = TEXT & " - ISG card: The RUN led is solid green, and FLT led is off"  & vbCrLf
    TEXT = TEXT & " - XH cards: All RX leds are flashing orange"  & vbCrLf
    TEXT = TEXT & " - EC2 card (if present): Link Fault led is blinking"  & vbCrLf
    RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
    If RESPONSE = 2 Then
        wscript.quit
    End If
   
    TEXT = "Now, we will check IP connectivity for each slot"  & vbCrLf
    TEXT = TEXT & "Click OK for send the ping of the death"  & vbCrLf
    RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
    If RESPONSE = 2 Then
        wscript.quit
    End If
   
    RETURNCODE=ping_internal()
    if RETURNCODE > 0 then
        TEXT = "ERROR: Can't ping all slots!"  & vbCrLf
        TEXT = TEXT & "Use the procedure for a manual transfer :-("  & vbCrLf
        RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
        If RESPONSE = 2 Then
            wscript.quit
        End If
    end if
   
    TEXT = "Successfull ping all slots"  & vbCrLf & vbCrLf
    TEXT = TEXT & "Step 7: Sending all firmware and configuration files to each slot"  & vbCrLf
    TEXT = TEXT & "Click OK for starting the process"  & vbCrLf
    RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
    If RESPONSE = 2 Then
        wscript.quit
    End If
   
    RETURNCODE=files_upload()
   
    if RETURNCODE <> 0 then
        TEXT = "Error meet during file transfer!"  & vbCrLf
        TEXT = TEXT & "Use the procedure for a manual transfer :-("  & vbCrLf
        RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
        If RESPONSE = 2 Then
            wscript.quit
        End If
    end if
   
    TEXT = "Step 8: Setting definitive rotary switch parameter"  & vbCrLf & vbCrLf
    TEXT = TEXT & " 1. power off the ATM switch"  & vbCrLf  & vbCrLf
    TEXT = TEXT & " 2. Extract each card (with the exeption of ISG card that is allready in good boot mode, standby ISG card that is allready extracted and XH cards)" & vbCrLf  & vbCrLf
    TEXT = TEXT & " 3. Change Rotary switch position to 8 for each extracted card (with the expection of Standby ISG card that is keept in position 4 and ISG card keept in position 0)"  & vbCrLf  & vbCrLf
    TEXT = TEXT & " 4. Re-insert ALL cards (with the exeption of ISG and XH cards that are allready insered)"  & vbCrLf  & vbCrLf
    TEXT = TEXT & " 5. Power on your ATM switch"  & vbCrLf  & vbCrLf
    TEXT = TEXT & " 6. Wait until the switch has started (ISG card with green RUN LED, and Standby ISG with slowly blink RUN LED)"  & vbCrLf  & vbCrLf
    RESPONSE = MsgBox (TEXT,vbOk,RELEASE)
   
    clean()
   
End Sub

Sub clean()
    ' This sub delete all used file
    ' Call at the normal end only
    Set fso = CreateObject("Scripting.FileSystemObject")
   
    If (fso.FileExists("hosts")) Then
        fso.DeleteFile("hosts")
    end if
   
    If (fso.FileExists("ftpcommands.txt")) Then
        fso.DeleteFile("ftpcommands.txt")
    end if
   
    If (fso.FileExists("ftpslot0.txt")) Then
        fso.DeleteFile("ftpslot0.txt")
    end if
   
   
End Sub

Sub FTP_isg()

    Set WshShell = WScript.CreateObject("WScript.Shell")
    Set objFSO = CreateObject("Scripting.FileSystemObject")

    If (objFSO.FileExists("hosts")) Then
        objFSO.DeleteFile("hosts")
    end if

    Set HOSTSFILE = objFSO.CreateTextFile("hosts")
    HOSTSFILE.WriteLine ("ipaddress=10.10.10.10")
    HOSTSFILE.Close
   
    If (objFSO.FileExists("ftpcommands.txt")) Then
        objFSO.DeleteFile("ftpcommands.txt")
    end if

    Set objFile = objFSO.CreateTextFile("ftpcommands.txt")
    objFile.WriteLine ("root")
    objFile.WriteLine ("MANAGER")
    objFile.WriteLine ("bin")
    objFile.WriteLine ("hash")
    objFile.WriteLine ("get vconfig")
    objFile.WriteLine ("cd /mnt/flash0")
    objFile.WriteLine ("put slot0\startup_isg.tz")
    objFile.WriteLine ("put hosts")
    objFile.WriteLine ("bye")
    objFile.Close

   
    RETURNCODE = WshShell.Run("ftp -s:ftpcommands.txt 172.16.255.1", 1, True)

    If (objFSO.FileExists("vconfig")) Then
        objFSO.DeleteFile("vconfig")
    else
        RETURNCODE = RETURNCODE + 1
    end if

    if RETURNCODE > 0 then
        TEXT = "Error meet during the FTP transfert to the ISG card!" & vbCrLf
        TEXT = TEXT & "Use the procedure for a manual transfer :-("
        RESPONSE = MsgBox (TEXT,vbOkCancel,RELEASE)
        If RESPONSE = 2 Then
            wscript.quit
        End If
    end if
   

End Sub

Sub Generate_ftp_script()
    Set objFSO = CreateObject("Scripting.FileSystemObject")

    If (objFSO.FileExists("ftpslot0.txt")) Then
        objFSO.DeleteFile("ftpslot0.txt")
    end if
   
    Set objFile = objFSO.CreateTextFile("ftpslot0.txt")
    objFile.WriteLine ("root")
    objFile.WriteLine ("MANAGER")
    objFile.WriteLine ("bin")
    objFile.WriteLine ("hash")
    objFile.WriteLine ("get vconfig")
    objFile.WriteLine ("cd /mnt/flash0")
   
    set fso = CreateObject("Scripting.FileSystemObject")
    Set WshShell = WScript.CreateObject("WScript.Shell")
    'Get the sub folder list
    set SUBDIR_LIST =  fso.GetFolder(".").SubFolders
  
    For Each SUBDIR In SUBDIR_LIST
        set OBJ_FILE_LIST =  fso.GetFolder(SUBDIR.Path).Files
       
        if SUBDIR.Name = "slot0" then
            For Each OBJ_FILE In OBJ_FILE_LIST
                'Skip the startup file: Allready uploaded
                if OBJ_FILE.Name <> "startup_isg.tz" then
                    objFile.WriteLine ("put slot0\" & OBJ_FILE.Name)   
                end if
           
            Next
       
        end if
   
    next
   
    objFile.WriteLine ("bye")
    objFile.Close
   
End Sub

Sub Check_file()

   ' Create the object
   TEXT = "Step 1: Checking firmware and configuration files presence and validity:" & vbCrLf
   TEXT = TEXT & "Check if your hardware ATM switch correspond to this configuration:" & vbCrLf & vbCrLf
    set fso = CreateObject("Scripting.FileSystemObject")
    'Get the sub folder list
    set SUBDIR_LIST =  fso.GetFolder(".").SubFolders
   
    If SUBDIR_LIST.Count = 0 Then

       MsgBox  "No slot directories found in script directory!" & vbCrLf & "There must be slot0, slot1, slot2, etc... directories that contain firmware and configurations files!"
        wscript.quit
    Else
  
        For Each SUBDIR In SUBDIR_LIST
            TEXT = TEXT & "- " & SUBDIR.Name & " "
            'Get the list of file in this sub folder
            set OBJ_FILE_LIST =  fso.GetFolder(SUBDIR.Path).Files
           
            FILE_CONFIG = 0
            FILE_STARTUP = 0
            FILE_HOSTS = 0
            FILE_VSM = 0
            FILE_MPRO = 0
            FILE_SLAVE = 0
            FILE_LCA = 0
            FILE_CE_LCA = 0
            FILE_ECC = 0
            FILE_EONE= 0
            FILE_OC= 0
           
            For Each OBJ_FILE In OBJ_FILE_LIST
           
                Select Case (OBJ_FILE.Name)

                Case "vsm.bin":
                    FILE_VSM = 1

                Case "mpro1.cod":
                    FILE_MPRO = 1

                Case "slave.cod":
                    FILE_SLAVE = 1
               
                Case "ce_lca.bin":
                    FILE_LCA = 1
                   
                Case "ecc.cod":
                    FILE_ECC = 1
                   
                Case "e1ds1.cod":
                    FILE_EONE = 1
               
                Case "oc3.cod":
                    FILE_OC = 1
               
                Case "hosts":
                    FILE_HOSTS = 1
               
                Case "startup_isg.tz":
                    FILE_STARTUP = 1
                   
                Case "config.cfg":
                    FILE_CONFIG = 1

                End Select
               
            Next
       
            if FILE_CONFIG = 1 then
                if FILE_HOSTS=1 and FILE_STARTUP=1 then
                    TEXT = TEXT & "front: ISG, back: Empty" & vbCrLf
                elseif FILE_CONFIG=1 and FILE_VSM=1 and FILE_MPRO=1 then
                    TEXT = TEXT & "front: VSM, back: DS1-4CS" & vbCrLf
                elseif FILE_CONFIG=1 and FILE_MPRO=1 then
                    TEXT = TEXT & "front: ACP, back: E3-2C" & vbCrLf
                elseif FILE_CONFIG=1 and FILE_ECC=1 and FILE_EONE=1 then
                    TEXT = TEXT & "front: ECC/EC2, back: E1-IMA" & vbCrLf
                elseif FILE_CONFIG=1 and FILE_ECC=1 and FILE_OC=1 then
                    TEXT = TEXT & "front: ECC/EC2, back: 155I/M/H-2" & vbCrLf
                elseif FILE_CONFIG=1 and FILE_SLAVE=1 and FILE_LCA=1 then
                    TEXT = TEXT & "front: CE, back: SI-4C" & vbCrLf
                else
                    TEXT = TEXT & "Unknown!" & vbCrLf
                end if
            else
                TEXT = TEXT & "Missing config.cfg file!" & vbCrLf
            end if
       
        Next

        RESPONSE = MsgBox (TEXT,vbOkCancel,"Checking Switch Files presence")
       
        If RESPONSE = 2 Then
            wscript.quit
        End If
       
    End If
   
End Sub

Function files_upload()
    files_upload=0
    ' Create the object
    set fso = CreateObject("Scripting.FileSystemObject")
    Set WshShell = WScript.CreateObject("WScript.Shell")
    'Get the sub folder list
    set SUBDIR_LIST =  fso.GetFolder(".").SubFolders
  
    For Each SUBDIR In SUBDIR_LIST
        set OBJ_FILE_LIST =  fso.GetFolder(SUBDIR.Path).Files
       
        if SUBDIR.Name = "slot0" then
            ' Do not transfert slot0 in the begining, keept it for the last transfert
            'Must includ and loop exit here
            WScript.Sleep 1
           
        else
            'Extract the number of the folder name: slot1
            'create a 2 element array cuting using the 't'
            TEMPO = Split(SUBDIR.Name, "t", -1, 1)
            SLOT_IP = 10 + TEMPO(1)
            For Each OBJ_FILE In OBJ_FILE_LIST
                RETURNCODE = WshShell.Run("tftp -i 10.10.10." & SLOT_IP &" put " & SUBDIR.Name & "\" & OBJ_FILE.Name, 1, True)
                if RETURNCODE > 0 then

                    WScript.Sleep 1000
                    RETURNCODE = WshShell.Run("tftp -i 10.10.10." & SLOT_IP &" put " & SUBDIR.Name & "\" & OBJ_FILE.Name, 1, True)
                    if RETURNCODE > 0 then
                        TEXT = "Error for TFTP transfer file: " & OBJ_FILE.Name
                        TEXT = TEXT & " into slot IP 10.10.10." & SLOT_IP
                        MsgBox TEXT
                    end if
                end if
                WScript.Sleep 1000
                files_upload = files_upload + RETURNCODE
            Next
       
        end if
       
    next
   
    'After all card, we upload to the ISG card
    Generate_ftp_script()
   
    ' The return code is allways 0 (good) with FTP
    RETURNCODE = WshShell.Run("ftp -s:ftpslot0.txt 10.10.10.10", 1, True)

    ' the FTP script download the vconfig file, this permit to check if FTP connection works

    If (fso.FileExists("vconfig")) Then
        fso.DeleteFile("vconfig")
    else
        RETURNCODE = RETURNCODE + 1
    end if

    files_upload = files_upload + RETURNCODE


End Function

Function Ping_Internal()
    Ping_Internal=0
    ' Create the object
    set fso = CreateObject("Scripting.FileSystemObject")
    Set WshShell = WScript.CreateObject("WScript.Shell")
    'Get the sub folder list
    set SUBDIR_LIST =  fso.GetFolder(".").SubFolders
  
    For Each SUBDIR In SUBDIR_LIST
        set OBJ_FILE_LIST =  fso.GetFolder(SUBDIR.Path).Files   
        'Extract the number of the folder name: slot1
        'create a 2 element array cuting using the 't'
        TEMPO = Split(SUBDIR.Name, "t", -1, 1)
        SLOT_IP = 10 + TEMPO(1)
       
        RETURNCODE = WshShell.Run("ping 10.10.10." & SLOT_IP & " -n 1", 1, True)
        Ping_Internal= Ping_Internal + RETURNCODE       
    next
   
End Function

Function Ping_Internal_old()
    Ping_Internal=0
   ' Create the object
    set fso = CreateObject("Scripting.FileSystemObject")
    'Get the sub folder list
    set SUBDIR_LIST =  fso.GetFolder(".").SubFolders
   
    Set WshShell = WScript.CreateObject("WScript.Shell")
   
    LAST_IP = 10 + SUBDIR_LIST.Count - 1
    For INDEX = 10 To LAST_IP
        RETURNCODE = WshShell.Run("ping 10.10.10." & INDEX & " -n 1", 1, True)
        Ping_Internal= Ping_Internal + RETURNCODE
    Next
       
End Function

Function check_ip(ipaddress,mask,defaultipgateway)

    strComputer = "."
    Set objWMIService = GetObject("winmgmts:" _
    & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")

    Set IPConfigSet = objWMIService.ExecQuery _
    ("Select * from Win32_NetworkAdapterConfiguration Where IPEnabled=TRUE")
 
    foundip=0
    foundmask=0
    foundgw=0

    For Each IPConfig in IPConfigSet
        If Not IsNull(IPConfig.IPAddress) Then
            For i=LBound(IPConfig.IPAddress) to UBound(IPConfig.IPAddress)
                if IPConfig.IPAddress(i)=ipaddress then
                    foundip=1
                end if
                'WScript.Echo "DEBUG IP: " & IPConfig.IPAddress(i)
            Next
        End If
        If Not IsNull(IPConfig.DefaultIPGateway) Then
            For i=LBound(IPConfig.DefaultIPGateway) to UBound(IPConfig.DefaultIPGateway)
                if IPConfig.DefaultIPGateway(i)=defaultipgateway then
                    foundgw=1
                end if
                'WScript.Echo "DEBUG GW : " & IPConfig.DefaultIPGateway(i)
            Next
        End If
    Next
   
    check_ip = 0
   
    if foundip=1 and foundgw=1 then
        check_ip = 1
    end if

End Function